HD-50W series normal dual switching power supply
Features:
·170~264VAC AC inputrange
·Small volume,low weight,high efficiency
·Protections:short circuit/over load
·LED indicator for power on
·100% full load burn-in test
·2 Years warranty
Model | HD-50A | HD-50B | HD-50C | ||||
output | DC voltage | CH1:5V | CH2:12V | CH1:5V | CH2:24V | CH1:12V | CH2:24V |
Voltage tolerance | ±2% | +4%~-8% | ±3% | +6%~-8% | ±3% | +6%~-8% | |
Rated current | 5A | 2A | 3A | 1.5A | 2A | 1.2A | |
Current range | 0.8~5A | 0.3~2A | 0.8~3A | 0.2~1.5A | 0.5~2A | 0.2~1.2A | |
Rated power | 49W | 51W | 52.8W | ||||
Ripple&noise | 80mvp-p | 100mvp-p | 80mvp-p | 120mvp-p | 100mvp-p | 120mvp-p | |
DCvoltage ADJ.range | CH1:-9%~+10% | ||||||
input | Voltage range | 170~263VAC,235~373VDC | |||||
frequency | 47~63HZ | ||||||
AC current | 0.8A/230VAC | ||||||
efficiency | 79% | 80% | 82% | ||||
Inrush current | Cold start current36A/230VAC | ||||||
Leakage current | < 2mA/240VAC | ||||||
protection | overload | Rated output power110%~150start over load protection | |||||
protection type:hiccup mode,auto-recovery after fault condition is removed | |||||||
----- | ----- | ||||||
----- | |||||||
environment | Working temp,humidity | -10℃~+60℃,20%~90%RH | |||||
Storage temp,humidity | -20℃~+85℃,10%~95%RH non-condensing | ||||||
Withstand vibration | 10~500HZ,2G10min/1cycle,period for 60 minutes,each axes | ||||||
safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||||
Fit standard | Safety standard | Compliance to UL1012 | |||||
EMC standard | Compliance to EN55022,CLASSA | ||||||
others | Dimension | 111*78*36mm(L*W*H) | |||||
Weight/packing | 0.27kg/50pcs/14.5kg/0.027m³/0.96CUFT | ||||||
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |