LPV-150W series LEDconstant voltage waterproof switching power supply
Features:
·Constantvoltage style power supply
·180~264VAC AC inputrange
·Small volume,low weight,high efficiency
·Protections: shortcircuit/over load/over voltage/over temp
·Cooling by freeair convection
·Fullyencapsulated with IP67 level
·100% full loadburn-in test
·2 Years warranty
Model | LPV-150-12 | LPV-150-24 | LPV-150-36 | LPV-150-48 | |
output | DC voltage | 12V | 24V | 36V | 48V |
Voltage tolerance | ±1% | ±1% | ±1% | ±1% | |
Rated current | 12.5A | 6.3A | 4.2A | 3.1A | |
Current range | 0~12.5A | 0~6.3A | 0~4.2A | 0~3.1A | |
Rated power | 150W | 151.2W | 151.2W | 148.8W | |
Ripple&noise | 120mvp-p | 150mvp-p | 180mvp-p | 180mvp-p | |
input | Voltage range | 180~264VAC,255~373VDC | |||
Frequency | 47~63HZ | ||||
AC current | 1.6A/230VAC | ||||
Efficiency | 82% | 84% | 84% | 85% | |
Inrush current | Cold start current40A/230VAC | ||||
Leakage current | <2.5mA/240VAC | ||||
protection | Over load | Rated output power105%~135%start over load protection | |||
Protection type: hiccup mode,auto-recovery after fault condition is removed | |||||
Over voltage | 15.6~17.8V | 30.6~33.2V | 42.6~44.2V | 54.8~56.6V | |
Protection type: hiccup mode,auto-recovery after fault condition is removed | |||||
Over temperature | Shell temp≥85℃,start over temperature protection | ||||
Protection mode: cutoff output,auto-recovery after temperature become normal | |||||
environment | Working temp,humidity | -10℃~+60℃,20%~90%RH | |||
Storage temp.humidity | -20℃~+85℃,10%~95%RH non condensing | ||||
Withstand vibration | 10~500HZ,2G10min/1cycle,period for 60minutes,each axes | ||||
safety | Withstand voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||
Isolated resistance | I/P-O/P、I/P-FG、O/P-FG:100Mohms/500VDC | ||||
Fits tandard | Safety standard | Fit UL1012,IP67 protect level | |||
EMC standard | Fit EN55022,CLASSA | ||||
Others | Dimension | 240*69*43mm(L*W*H) | |||
Weight/packing | 1.26kg/20pcs/26kg/0.033 m³/1.15CUFT | ||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |