Features:
·Universal AC input/Full range
·Withstand 300VAC surge input for 5 second
·Miniature size and 1U low profile,low weight
·Protections:Short circuit/Overload/Over voltage
·Cooling by free air convection
·No load power consumption<0.5W
·Operating altitude up to 5000 meters(Note6)
·LED indicator for power on
·100% full load burn-in test
·High efficiency,long life and high reliability
·3 years warranty
Model | LRS-50-5 | LRS-50-12 | LRS-50-15 | LRS-50-24 | LRS-50-36 | LRS-50-48 | |
output | DC voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Rated current | 10A | 4.2A | 3.4A | 2.2A | 1.45A | 1.1A | |
Current range | 0~10A | 0~4.2A | 0~3.4A | 0~2.2A | 0~1.45A | 0~1.1A | |
Rated power | 50W | 50.4W | 51W | 52.8W | 52.2W | 52.8W | |
Ripple&noise | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
DC voltage ADJ. range | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
Voltage toleranceNote.3 | ±3% | ±2% | ±1% | ±1% | ±1% | ±1% | |
Line regulationNote.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load regulationNote.5 | ±2% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Setup,rise,hold up time | 800ms,30ms,30ms/230VAC(full load) | ||||||
input | Voltage range | 90~264VAC,127~373VDC | |||||
Frequency range | 47~63HZ | ||||||
AC current | 0.95A/115VAC 0.56A/230VAC | ||||||
Inrush current | Cold start 45A/230VAC | ||||||
Efficiency | 83% | 86% | 87% | 88% | 89% | 90% | |
Leakage current | <0.75mA/240VAC | ||||||
protection | overload | Rated output power110%~150% start over load protection | |||||
protection type:hiccup mode,auto-recovery after fault condition is removed | |||||||
Over voltage | Rated output voltage 115%~135% Start over voltage protection | ||||||
Protection type:hiccup mode,auto-recovery after fault condition is removed | |||||||
environment | Working temp,humidity | -30℃~+70℃(Please refer to“derating curve”) 20%~90%RH Non-condensing | |||||
Storage temp,humidity | -40℃~+85℃,10%~95%RH non-condensing | ||||||
Withstand vibration | 10~500HZ,2G10min/1cycle,period for 60 minutes,each axes | ||||||
safety | Withstand voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||||
Fit standard | Safety standards | Compliance to UL60950-1,TUV EN60950-1,GB4943 | |||||
EMC emission | Compliance to EN55032(CISPR22)Class A,GB9254 Class B,EN55014,EN61000-3-2,3 | ||||||
EMC immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61000-6-1 | ||||||
others | Dimension | 99*82*30mm(L*W*H) | |||||
Weight/packing | 0.21kg/60pcs/13.6kg/0.025m³/0.88CUFT | ||||||
MTBF | ≥630K hrs min. MIL-HDBK-217F(25℃) | ||||||
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.Load regulation is measured from 0% to 100% rated load 6.The ambient temperature derating of 5℃/1000 m is needed for operating altitude greater than 2000m(6500ft) 7.The power supply is considered as a component which will be installed into a finalequipment.The final equipment must be re-confirmed that it still meets EMC directives.For guidance on how to perform these EMC tests. |