MS-60W series MINI single switching power supply
Features:
·Universal AC inputrange
·Small volume,low weight,high efficiency
·Protections:short circuit/over load
·cooling by free air convection
·LED indicator for power on
·100% full load burn-in test
·No load consumption<0.8W
·2 Years warranty
Model | MS-60-12 | MS-60-24 |
| |
output | DC voltage | 12V | 24V |
|
Voltage tolerance | ±2% | ±2% |
| |
Rated current | 5A | 2.5A |
| |
Current range | 0~5A | 0~2.5A |
| |
Rated power | 60W | 60W |
| |
Ripple&noise | 150mvp-p | 180mvp-p |
| |
DCvoltage ADJ.range | ±10% | ±10% |
| |
input | Voltage range | 90-264VAC,135~373VDC | ||
Setup,rise,hold up time | 800ms,30ms,20ms/230VAC,1200ms,30ms,20ms/115VAC | |||
frequency | 47~63HZ | |||
AC current | 1.2A/115VAC 0.60A/230VAC | |||
efficiency | 85% | 86% |
| |
Inrush current | Cold start current 45A/230VAC | |||
Leakage current | < 1mA/240VAC | |||
protection | overload | Rated output power110%~135% start over load protection | ||
protection type:hiccup mode,auto-recovery after fault condition is removed | ||||
|
| |||
| ||||
|
| |||
| ||||
environment | Working temp,humidity | -25℃~+50℃,20%~90%RH | ||
Storage temp,humidity | -40℃~+85℃,10%~95%RH non-condensing | |||
Withstand vibration | 10~500HZ,2G10min/1cycle,period for 60 minutes,each axes | |||
safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | |||
Fit standard | Safety standard | Compliance to UL1012,UL60950-1,GB4943 | ||
EMC standard | Compliance to EN55022,EN61000-3-2,CLASSA | |||
others | Dimension | 111*78*30mm (L*W*H) | ||
Weight/packing | 0.26kg/50pcs/14kg/0.027m³/0.95CUFT | |||
MTBF | 350K hrs min. MIL-HDBK-217F(25℃) | |||
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |