S-100W seriesnormal single switchingpower supply
Features:
·AC input voltage range selected by switch
·Small volume,low weight,high efficiency
·Protections:short circuit/over load
·cooling by free air convection
·LED indicator for power on
·100% full load burn-in test
·2 Years warranty
Model | S-100-5 | S-100-12 | S-100-15 | S-100-24 | S-100-36 | S-100-48 | |
output | DC voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Voltage tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | |
Rated current | 20A | 8.5A | 6.7A | 4.5A | 2.8A | 2A | |
Current range | 0~20A | 0~8.5A | 0~6.7A | 0~4.5A | 0~2.8A | 0~2A | |
Rated power | 100W | 102W | 100.5W | 108W | 100.8W | 96W | |
Ripple&noise | 100mvp-p | 120mvp-p | 120mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | |
DCvoltage ADJ.range | -9%~+10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
input | Voltage range | 90~132VAC/180~264VAC(selected by switch),255~373VDC | |||||
frequency | 47~63HZ | ||||||
AC current | 2.4A/115VAC,1.2A/230VAC | ||||||
efficiency | 78% | 80% | 80% | 82% | 82% | 83% | |
Inrush current | Cold start current18A/115VAC,36A/230VAC | ||||||
Leakage current | < 3.5mA/240VAC | ||||||
protection | overload | Rated output power115%~150% start over load protection | |||||
protection type:cutoff output,recovery after restart power | |||||||
----- | ----- | ||||||
----- | |||||||
----- | ----- | ||||||
----- | |||||||
environment | Working temp,humidity | -10℃~+60℃,20%~90%RH | |||||
Storagetemp,humidity | -20℃~+85℃,10%~95%RH non-condensing | ||||||
Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes | ||||||
safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||||
Fitstandard | Safety standard | Compliance to UL1012 | |||||
EMC standard | Compliance to EN55022,CLASSA | ||||||
others | Dimension | 199*98*38mm(L*W*H) | |||||
Weight/packing | 0.6kg/30pcs/19kg/0.034 m³/1.2CUFT | ||||||
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |