T-120W series normal triple switchingpower supply
Features:
·AC input voltage range selected by switch
·Small volume,low weight,high efficiency
·Protections:short circuit/over load/over voltage
·LED indicator for power on
·100% full load burn-in test
·2 Years warranty
Model | T-120A | T-120B | ||||||
output | DC voltage | CH1:+5V | CH2:+12V | CH3:-5V | CH1:+5V | CH2:+12V | CH3:-12V | |
Voltage tolerance | ±2% | ±6% | ±6% | ±2% | ±6% | ±6% | ||
Rated current | 11A | 5A | 1A | 11A | 4.5A | 1A | ||
Current range | 2~11A | 0.5~5A | 0.2~1A | 2~11A | 0.5~4.5A | 0.2~1A | ||
Rated power | 120W | 121W | ||||||
Ripple&noise | 80mvp-p | 120mvp-p | 80mvp-p | 80mvp-p | 120mvp-p | 120mvp-p | ||
DCvoltage ADJ.range | CH1:-9%~+10% | |||||||
input | Voltage range | 90~132VAC/180~264VAC(selected by switch),255~373VDC | ||||||
frequency | 47~63HZ | |||||||
AC current | 2.8A/115VAC,1.6A/230VAC | |||||||
efficiency | 77% | 77% | ||||||
Inrush current | Cold start current 30A/115VAC,60A/230VAC | |||||||
Leakage current | < 3.5mA/240VAC | |||||||
protection | overload | Rated output power110%~150start over load protection | ||||||
protection type:cutoff output,recovery after restart power | ||||||||
over voltage | CH1、CH2:115~135% | |||||||
protection type:cutoff output,recovery after restart power | ||||||||
environment | Working temp,humidity | -10℃~+60℃,20%~90%RH | ||||||
Storagetemp,humidity | -20℃~+85℃,10%~95%RH non-condensing | |||||||
Withstand vibration | 10~500HZ,2G10min/1cycle,period for 60 minutes,each axes | |||||||
safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | |||||||
Fitstandard | Safety standard | Compliance toUL1012 | ||||||
EMC standard | Compliance toEN55022,CLASSA | |||||||
others | Dimension | 199*110*50mm(L*W*H) | ||||||
Weight/packing | 0.85kg/24pcs/21.5kg/0.043m³/1.51CUFT | |||||||
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. | |||||||