T-30W series normal triple switchingpower supply
Features:
·AC input voltage range selected by switch
·Small volume,low weight,high efficiency
·Protections:short circuit/over load
·LED indicator for power on
·100% full load burn-in test
·2 Years warranty
Model | T-30A | T-30B | ||||||
output | DC voltage | CH1:+5V | CH2:+12V | CH3:-5V | CH1:+5V | CH2:+12V | CH3:-12V | |
Voltage tolerance | ±2% | +4%~-6% | +5%~-10% | ±2% | +4%~-6% | +5%~-10% | ||
Rated current | 3A | 1A | 0.5A | 3A | 1A | 0.5A | ||
Current range | 0.6~3A | 0.1~1A | 0.1~0.5A | 0.6~3A | 0.1~1A | 0.1~0.5A | ||
Rated power | 30W | 33W | ||||||
Ripple&noise | 80mvp-p | 100mvp-p | 100mvp-p | 80mvp-p | 100mvp-p | 100mvp-p | ||
DCvoltage ADJ.range | CH1:-9%~+10% | |||||||
input | Voltage range | 90~132VAC/180~264VAC(selected by switch),255~373VDC | ||||||
frequency | 47~63HZ | |||||||
AC current | 0.8A/115VAC,0.45A/230VAC | |||||||
efficiency | 73% | 74% | ||||||
Inrush current | Cold start current18A/115VAC,36A/230VAC | |||||||
Leakage current | < 2mA/240VAC | |||||||
protection | overload | Rated output power110%~150start over load protection | ||||||
protection type :part layer type current limit,auto-recovery after fault condition is removed | ||||||||
----- | ----- | |||||||
----- | ||||||||
environment | Working temp,humidity | -10℃~+60℃,20%~90%RH | ||||||
Storagetemp,humidity | -20℃~+85℃,10%~95%RH non-condensing | |||||||
Withstand vibration | 10~500HZ,2G10min/1cycle,period for 60 minutes,each axes | |||||||
safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | |||||||
Fitstandard | Safety standard | Compliance to UL1012 | ||||||
EMC standard | Compliance to EN55022,CLASSA | |||||||
others | Dimension | 129*98*38mm(L*W*H) | ||||||
Weight/packing | 0.4kg/45pcs/19kg/0.034m³/1.2CUFT | |||||||
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. | |||||||