T-60W series normal triple switchingpower supply
Features:
·universalACinput
·Small volume,low weight,high efficiency
·Protections:short circuit/over load/over voltage
·LED indicator for power on
·100% full load burn-in test
·2 Years warranty
Model | T-60A | T-60B | |||||
output | DC voltage | CH1:+5V | CH2:+12V | CH3:-5V | CH1:+5V | CH2:+12V | CH3:-12V |
Voltage tolerance | ±2% | ±6% | ±3% | ±2% | ±6% | ±3% | |
Rated current | 5A | 2.5A | 0.5A | 5A | 2.5A | 0.5A | |
Current range | 0.6~5A | 0.2~2.5A | 0~0.5A | 0.6~5A | 0.2~2.5A | 0~0.5A | |
Rated power | 57.5W | 61W | |||||
Ripple&noise | 80mvp-p | 100mvp-p | 80mvp-p | 80mvp-p | 100mvp-p | 100mvp-p | |
DCvoltage ADJ.range | CH1:-9%~+10% | ||||||
input | Voltage range | 90~264VAC,127~373VDC | |||||
frequency | 47~63HZ | ||||||
AC current | 1.8A/115VAC,0.9A/230VAC | ||||||
efficiency | 73% | 74% | |||||
Inrush current | Cold start current25A/115VAC,50A/230VAC | ||||||
Leakage current | < 2mA/240VAC | ||||||
protection | overload | Rated output power110%~150start over load protection | |||||
| protection type:hiccup mode,auto-recovery after fault condition is removed | ||||||
over voltage | CH1:115%~135% | ||||||
| protection type:hiccup mode,auto-recovery after fault condition is removed | ||||||
environment | Working temp,humidity | -10℃~+60℃,20%~90%RH | |||||
Storagetemp,humidity | -20℃~+85℃,10%~95%RH non-condensing | ||||||
Withstand vibration | 10~500HZ,2G10min/1cycle,period for 60 minutes,each axes | ||||||
safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||||
Fitstandard | Safety standard | Compliance to UL1012 | |||||
EMC standard | Compliance to EN55022,CLASSA | ||||||
others | Dimension | 159*97*38mm(L*W*H) | |||||
Weight/packing | 0.56kg/45pcs/26kg/0.041m³/1.45CUFT | ||||||
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |